Attributes
| Short Description | Venturi Dispenser, wall or drum mounted, 1 chemistry w/ 1 dispenser |
|---|---|
| Technologies | Venturi Dispensers |
| Markets | Industrial |
| Applications | Cutting Fluid Dilution, Lubricant Dilution, Coolant Dilution, Filling Totes & Drums |
| Regions | Europe, North America |
| Model Count | 5 |
Description
Venturi Dispenser, wall or drum mounted, 1 chemistry w/ 1 dispenser
HydroMaster drum or wall-mounted proportioners automatically mix liquid cleaning and sanitizing concentrates with water and dispense the diluted solution into any container.
Any size container of concentrate can be used with the HydroMaster because there’s no need to tip the container to pour the contents.
**Features & Benefits**
#### Multiple mounting options allow for greater installation options
HydroMaster can either be drum or wall-mounted resulting in the ability to adjust the location where the unit is installed depending on the location of the chemical container.
#### Utilizes Hydro Systems standard tips that allow for up to 20% better dilution accuracy
The use of standard Hydro Systems metering tips allow for more accurate dilution performance that results in more accurate chemical usage. Other products will result in more chemistry than what is needed resulting in wasted chemistry or not enough chemistry is used resulting in the need for a rewash.
#### Features chemically resistant materials that result in longer lasting equipment
HydroMaster features chemically resistant materials that provide for longer lasting equipment life.
**Common Questions**
*Does HydroMaster require electrical power to operate?*
No. The venturi is operated based on hydro power.
*Does HydroMaster use standard push in metering tips?*
No. There unique threaded types that need to be used with HydroMaster that come with the unit
*When it comes to installing HydroMaster what are my options?*
HydroMaster can be installed through the attachment to a wall or mounted on top of a chemical drum using an adapter that comes with the HydroMaster.
*Does HydroMaster come standard with a chemical pick-up tube?*
Yes.
*Does the water inlet hose come standard with HydroMaster?*
No. The water inlet hose needs to be ordered separately.
Variations (45)
204
| Description | Wall mounted |
|---|---|
| Flow Rate(GPM) | 4.8 |
| # of Products | 1 |
| Approximate Dilution Range | 4.5:1 |
| Section | Models & Specifications |
206
| Description | Wall/drum mounted |
|---|---|
| Flow Rate(GPM) | 4.8 |
| # of Products | 1 |
| Approximate Dilution Range | 4.5:1 |
| Section | Models & Specifications |
208
| Description | High concentration |
|---|---|
| Flow Rate(GPM) | 2.5 |
| # of Products | 1 |
| Approximate Dilution Range | 1:1 |
| Section | Models & Specifications |
216
| Description | Wall/drum mounted |
|---|---|
| Flow Rate(GPM) | 9.8 |
| # of Products | 1 |
| Approximate Dilution Range | 5:1 |
| Section | Models & Specifications |
220
| Description | Wall/drum mounted |
|---|---|
| Flow Rate(GPM) | 16.8 |
| # of Products | 1 |
| Approximate Dilution Range | 8:1 |
| Section | Models & Specifications |
238100
| DESCRIPTION | Strainer washer |
|---|---|
| Section | HydroMaster Model 204 |
506500
| DESCRIPTION | Hose swivel |
|---|---|
| Section | HydroMaster Model 204 |
502000
| DESCRIPTION | Ball valve |
|---|---|
| Section | HydroMaster Model 204 |
234300
| DESCRIPTION | Nipple |
|---|---|
| Section | HydroMaster Model 204 |
6150-K
| DESCRIPTION | Mounting bracket |
|---|---|
| Section | HydroMaster Model 204 |
690015
| DESCRIPTION | Metering tip (kit) |
|---|---|
| Section | HydroMaster Model 204 |
440121
| DESCRIPTION | Eductor assy., (includes a & b) |
|---|---|
| Section | HydroMaster Model 204 |
440100
| DESCRIPTION | Eductor only |
|---|---|
| Section | HydroMaster Model 204 |
440101
| DESCRIPTION | Suction stub |
|---|---|
| Section | HydroMaster Model 204 |
5058-9A
| DESCRIPTION | Suction tube assy. |
|---|---|
| Section | HydroMaster Model 204 |
616100
| DESCRIPTION | (includes c, d, e &f)Tubing, 1/4" x 7" |
|---|---|
| Section | HydroMaster Model 204 |
505809
| DESCRIPTION | 1/2" ID tubing |
|---|---|
| Section | HydroMaster Model 204 |
250006
| DESCRIPTION | Ceramic weight |
|---|---|
| Section | HydroMaster Model 204 |
10076301
| DESCRIPTION | Foot valve, Viton* |
|---|---|
| Section | HydroMaster Model 204 |
5058-4 DA
| DESCRIPTION | Discharge tube assy. |
|---|---|
| Section | HydroMaster Model 204 |
10090910
| DESCRIPTION | Bung adapter assy. |
|---|---|
| Section | HydroMaster Model 206 |
505804
| DESCRIPTION | 1/2" ID tubing |
|---|---|
| Section | HydroMaster Model 206 |
615000
| DESCRIPTION | Mounting bracket |
|---|---|
| Section | HydroMaster Model 208 |
440321
| DESCRIPTION | Eductor assy.(includes a & b) |
|---|---|
| Section | HydroMaster Model 208 |
440301
| DESCRIPTION | Eductor only |
|---|---|
| Section | HydroMaster Model 208 |
10031101
| DESCRIPTION | Suction tube assy.(includes c, d, e & f) |
|---|---|
| Section | HydroMaster Model 208 |
10031100
| DESCRIPTION | Foot valve, Viton* |
|---|---|
| Section | HydroMaster Model 208 |
276700
| DESCRIPTION | Swivel connector |
|---|---|
| Section | HydroMaster Model 216 |
607600
| DESCRIPTION | Ball valve |
|---|---|
| Section | HydroMaster Model 216 |
360900
| DESCRIPTION | 3/8" Reducing nipple |
|---|---|
| Section | HydroMaster Model 216 |
615200
| DESCRIPTION | Retainer ring |
|---|---|
| Section | HydroMaster Model 216 |
6162-A
| DESCRIPTION | Bung adapter assy. |
|---|---|
| Section | HydroMaster Model 216 |
440700
| DESCRIPTION | Eductor body |
|---|---|
| Section | HydroMaster Model 216 |
440701
| DESCRIPTION | Suction stub |
|---|---|
| Section | HydroMaster Model 216 |
5058-4DM
| DESCRIPTION | Suction tube assy.(includes a, b, c & d) |
|---|---|
| Section | HydroMaster Model 216 |
5201-A
| DESCRIPTION | Discharge tube assy |
|---|---|
| Section | HydroMaster Model 216 |
607900
| DESCRIPTION | Hose swivel |
|---|---|
| Section | HydroMaster Model 220 |
270700
| DESCRIPTION | Hose washer |
|---|---|
| Section | HydroMaster Model 220 |
611500
| DESCRIPTION | Adaptor |
|---|---|
| Section | HydroMaster Model 220 |
508700
| DESCRIPTION | Ball valve |
|---|---|
| Section | HydroMaster Model 220 |
508800
| DESCRIPTION | Nipple |
|---|---|
| Section | HydroMaster Model 220 |
6158-K
| DESCRIPTION | Mounting bracket |
|---|---|
| Section | HydroMaster Model 220 |
5095-K
| DESCRIPTION | Eductor assembly (includes a) |
|---|---|
| Section | HydroMaster Model 220 |
440201
| DESCRIPTION | Suction stub only |
|---|---|
| Section | HydroMaster Model 220 |
50844A
| DESCRIPTION | Discharge tube assembly |
|---|---|
| Section | HydroMaster Model 220 |
Specifications
| Markets | Industrial |
|---|---|
| Applications | Cutting Fluid Dilution, Lubricant Dilution, Coolant Dilution, Filling Totes & Drums |
| Technology | Venturi Dispensers |
| Region Availability | Europe, North America |